We Deal In different types of laminar air flow. it is used in pharmaceutical industries and laboratory.We are one of the best manufacturers in this industry.
₹ 62500 / Unit Get Latest Price
| Working Width | 2 ft |
| Cleanroom Class | ISO 5 |
| Material | Stainless Steel |
| Type | Horizontal |
| Surface Finish | Polished |
| Filter Type | HEPA H14 |
| Work Zone Height | 2 ft |
| Front Sash Type | Acrylic Shield |
| Efficiency(%) | 99.99% |
| Air Flow | 90FPM |
| Brand | SR Air System |
| Model Name/Number | SR-HLAF-2022-023 |
| Size | 2x2x6 |
| Usage/Application | Laboratory |
| Blower Type | Centrifugal |
| Color | Silver |
| Voltage | 220-240V |
| Illumination | Fluorescent |
| Noise Level | 50db |
| Power Supply | 230 V AC |
| Lighting Type | LED |
| Power | 230VAC |
| MOC | 304-stainless steel |
| Shape | RECTANGULAR |
| Wall Thickness | 1MM |
| Efficiency | 99.999 |
| Electrical Supply V | 1 PHASE |
| Filtration Capacity Microns | 0.3MICRON |
| Filtration Grade | H14 |
| Flow Capacity Range | 15-20 |
| Iso Certified | YES |
| Pre Filter | 10 MICRON |
| Voltage V | 230VAC |
| Weight G | 50KG |
| Country of Origin | Made in India |
Minimum order quantity: 1 Unit
A Horizontal Laminar Air Flow (HLAF) System is a clean airflow unit that provides a continuous stream of sterile, particle-free air from the back of the unit to the front, ensuring protection from contamination. It is widely used in laboratories, cleanrooms, and industries requiring controlled environments.
1. Horizontal Laminar Air Flow Specifications| Parameter | Details |
|---|---|
| Material | Stainless Steel (SS 304/316) or Powder-Coated Mild Steel (MS) |
| Airflow Direction | Horizontal (Back to Front) |
| Filtration System | HEPA Filter (99.99% efficiency at 0.3 µm) / ULPA Filter (99.999% efficiency at 0.12 µm) |
| Air Velocity | 0.3 - 0.5 m/s (60 - 90 feet per minute) |
| Pre-Filters | 5 - 10 µm efficiency for larger particles |
| Noise Level | Below 65 dB |
| Lighting | LED Light, UV Germicidal Lamp (Optional) |
| Work Surface | Stainless Steel (SS 304/316) |
| Power Supply | 220V/50Hz or 110V/60Hz |
| Interlocking System | Mechanical/Electromagnetic (Optional) |
Uniform airflow: Air moves in a straight-line path, reducing turbulence.
Low contamination risk: Provides continuous clean airflow, preventing particle accumulation.
Ergonomic Design: Allows open front access, making it ideal for sample handling.
Pharmaceutical & Biotech:
Used in drug manufacturing, sterile compounding, and microbiology labs.
Prevents contamination of culture media and chemical solutions.
Microbiology & Pathology Labs:
Provides aseptic conditions for working with bacterial cultures, tissue cultures, and DNA/RNA samples.
Hospitals & Healthcare:
Used in IV preparation rooms, surgical instrument preparation, and sterile storage areas.
Food & Beverage Industry:
Maintains hygiene during food packaging and quality control processes.
Semiconductors & Electronics:
Ensures dust-free environments for chip manufacturing and circuit board assembly.
₹ 75000 / Piece Get Latest Price
| Working Width | 2 ft |
| Cleanroom Class | ISO 5 |
| Material | 304-SS JINDAL |
| Type | Horizontal |
| Surface Finish | Polished |
| Filter Type | HEPA H14 |
| Work Zone Height | 2 ft |
| Front Sash Type | Folding |
| Brand | SR Air System |
| Model Name/Number | sr air-22-23 |
| Size | 2x2x6 |
| Usage/Application | Pharmaceutical Industry |
| Blower Type | Centrifugal |
| Color | Silver |
| Voltage | 240 V |
| Illumination | Fluorescent |
| Noise Level | 60 db |
| Power Supply | 230 V AC |
| Frequency | 60 Hz |
| Country of Origin | Made in India |
| Height | 5.5 ft |
Minimum order quantity: 1 Piece
Laminar Air Flow refers to a smooth, orderly flow of air in parallel layers or streams, with little to no disruption or turbulence between them. This type of airflow is characterized by a consistent and uniform motion of air molecules along straight or gently curved paths.
Here are the key characteristics of laminar airflow:
Smooth and Steady: Air moves in layers without chaotic fluctuations, meaning that the velocity of the airflow is constant in each layer.
Parallel Layers: The airflow occurs in parallel layers that do not mix or interfere with each other. Each layer flows smoothly over the others, without causing turbulence.
Low Velocity: Laminar flow typically occurs at lower velocities, where air molecules move at a slower pace and in a more uniform direction.
Viscosity Dominance: In laminar flow, the effects of air viscosity are dominant. Higher viscosity results in smoother, laminar flow because it prevents the air from becoming turbulent.
Reynolds Number: The onset of laminar flow is associated with a low Reynolds number (typically less than 2000). This number is a dimensionless quantity that helps predict flow patterns in different fluid dynamics scenarios.
Clean Rooms: Laminar air flow is often used in controlled environments like clean rooms or sterile laboratories where contamination must be minimized. The air is filtered and flows in a smooth, directional pattern to avoid bringing in contaminants.
HVAC Systems: Certain ventilation systems use laminar airflow to maintain air quality and temperature control in sensitive environments.
Aircraft Engineering: In some parts of aircraft, laminar airflow is desirable to reduce drag and improve fuel efficiency.
Unlike turbulent flow, which is chaotic and irregular, laminar flow is highly organized. Turbulent flow, which occurs at higher velocities or with lower viscosity, can lead to swirls, eddies, and vortices in the air, creating much more resistance.
In short, laminar air flow is efficient, stable, and crucial for environments where contamination control or optimal aerodynamic performance is necessary.
₹ 62500 / Unit Get Latest Price
| Working Width | 2 ft |
| Cleanroom Class | ISO 5 |
| Material | Stainless Steel |
| Type | Horizontal |
| Surface Finish | Polished |
| Brand | SR AIR SYSTEM |
| Usage/Application | Laboratory |
| Color | Silver |
| Voltage | 230 V |
| Frequency | 50 Hz |
| Front Window Type | Glass |
| Power Supply | AC |
| Country of Origin | Made in India |
| Height | 3 ft |
Minimum order quantity: 1 Unit
A Horizontal Laminar Air Flow (HLAF) System is a clean airflow unit that provides a continuous stream of sterile, particle-free air from the back of the unit to the front, ensuring protection from contamination. It is widely used in laboratories, cleanrooms, and industries requiring controlled environments.
1. Horizontal Laminar Air Flow Specifications| Parameter | Details |
|---|---|
| Material | Stainless Steel (SS 304/316) or Powder-Coated Mild Steel (MS) |
| Airflow Direction | Horizontal (Back to Front) |
| Filtration System | HEPA Filter (99.99% efficiency at 0.3 µm) / ULPA Filter (99.999% efficiency at 0.12 µm) |
| Air Velocity | 0.3 - 0.5 m/s (60 - 90 feet per minute) |
| Pre-Filters | 5 - 10 µm efficiency for larger particles |
| Noise Level | Below 65 dB |
| Lighting | LED Light, UV Germicidal Lamp (Optional) |
| Work Surface | Stainless Steel (SS 304/316) |
| Power Supply | 220V/50Hz or 110V/60Hz |
| Interlocking System | Mechanical/Electromagnetic (Optional) |
Uniform airflow: Air moves in a straight-line path, reducing turbulence.
Low contamination risk: Provides continuous clean airflow, preventing particle accumulation.
Ergonomic Design: Allows open front access, making it ideal for sample handling.
Pharmaceutical & Biotech:
Used in drug manufacturing, sterile compounding, and microbiology labs.
Prevents contamination of culture media and chemical solutions.
Microbiology & Pathology Labs:
Provides aseptic conditions for working with bacterial cultures, tissue cultures, and DNA/RNA samples.
Hospitals & Healthcare:
Used in IV preparation rooms, surgical instrument preparation, and sterile storage areas.
Food & Beverage Industry:
Maintains hygiene during food packaging and quality control processes.
Semiconductors & Electronics:
Ensures dust-free environments for chip manufacturing and circuit board assembly.
₹ 67500 / Piece Get Latest Price
| Working Width | 3 ft |
| Cleanroom Class | ISO 5 |
| Material | 304-SS |
| Usage/Application | Hospital |
| Brand | SR AIR |
| Surface Finish | Polished |
| Air Flow | VERTICAL |
| Efficiency(%) | 99.99% |
| Model Name/Number | SR-VLAF-24-25 |
| Size | 3X2X2 |
| Height | 7FT OD |
| Country of Origin | Made in India |
A Vertical Laminar Air Flow (VLAF) System provides a continuous stream of sterile, particle-free air from the top to the bottom, ensuring a contamination-free environment. It is commonly used in industries requiring high cleanliness standards, such as pharmaceuticals, biotechnology, and electronics manufacturing.
1. Vertical Laminar Air Flow Specifications| Parameter | Details |
|---|---|
| Material | Stainless Steel (SS 304/316) or Powder-Coated Mild Steel (MS) |
| Airflow Direction | Vertical (Top to Bottom) |
| Filtration System | HEPA Filter (99.99% efficiency at 0.3 µm) / ULPA Filter (99.999% efficiency at 0.12 µm) |
| Air Velocity | 0.3 - 0.5 m/s (60 - 90 feet per minute) |
| Pre-Filters | 5 - 10 µm efficiency for larger particles |
| Noise Level | Below 65 dB |
| Lighting | LED Light, UV Germicidal Lamp (Optional) |
| Work Surface | Stainless Steel (SS 304/316) |
| Power Supply | 220V/50Hz or 110V/60Hz |
| Interlocking System | Mechanical/Electromagnetic (Optional) |
Downward airflow: Reduces contamination risk by pushing particles away from the work surface.
Safer for operator: Unlike horizontal LAF, vertical airflow does not blow directly at the user.
Ideal for handling hazardous samples (when combined with bio-safety cabinets).
Pharmaceutical & Biotechnology:
Used in drug formulation, sterile compounding, and quality control labs.
Ensures contamination-free environments for vaccine production.
Microbiology & Pathology Labs:
Provides aseptic conditions for handling bacteria, fungi, and tissue cultures.
Hospitals & Healthcare:
Used in sterile surgical areas, cleanrooms, and ICU preparation rooms.
Food & Beverage Industry:
Maintains hygiene in food quality testing and packaging.
Semiconductors & Electronics:
Prevents dust contamination in microchip and circuit board assembly.
Aerospace & Defense:
Ensures clean manufacturing environments for precision components.
₹ 80000 / Piece Get Latest Price
| Working Width | 4 ft |
| Cleanroom Class | ISO 5 |
| Size(ft) | 3 x 2 x 2 |
| Material | Stainless Steel |
| Type | Horizontal |
| Size | 3' X 2' x 2' |
| Usage/Application | Laboratory |
| Surface Finish | Polished |
| Efficiency(%) | 99.99% |
| Brand | SR AIR |
| Air Flow | HORIZONTAL TYPE |
| Electrical Socket | 15 Amp |
Minimum order quantity: 1 Piece
A Horizontal Laminar Air Flow (HLAF) System is a clean airflow unit that provides a continuous stream of sterile, particle-free air from the back of the unit to the front, ensuring protection from contamination. It is widely used in laboratories, cleanrooms, and industries requiring controlled environments.
1. Horizontal Laminar Air Flow Specifications| Parameter | Details |
|---|---|
| Material | Stainless Steel (SS 304/316) or Powder-Coated Mild Steel (MS) |
| Airflow Direction | Horizontal (Back to Front) |
| Filtration System | HEPA Filter (99.99% efficiency at 0.3 µm) / ULPA Filter (99.999% efficiency at 0.12 µm) |
| Air Velocity | 0.3 - 0.5 m/s (60 - 90 feet per minute) |
| Pre-Filters | 5 - 10 µm efficiency for larger particles |
| Noise Level | Below 65 dB |
| Lighting | LED Light, UV Germicidal Lamp (Optional) |
| Work Surface | Stainless Steel (SS 304/316) |
| Power Supply | 220V/50Hz or 110V/60Hz |
| Interlocking System | Mechanical/Electromagnetic (Optional) |
Uniform airflow: Air moves in a straight-line path, reducing turbulence.
Low contamination risk: Provides continuous clean airflow, preventing particle accumulation.
Ergonomic Design: Allows open front access, making it ideal for sample handling.
Pharmaceutical & Biotech:
Used in drug manufacturing, sterile compounding, and microbiology labs.
Prevents contamination of culture media and chemical solutions.
Microbiology & Pathology Labs:
Provides aseptic conditions for working with bacterial cultures, tissue cultures, and DNA/RNA samples.
Hospitals & Healthcare:
Used in IV preparation rooms, surgical instrument preparation, and sterile storage areas.
Food & Beverage Industry:
Maintains hygiene during food packaging and quality control processes.
Semiconductors & Electronics:
Ensures dust-free environments for chip manufacturing and circuit board assembly.
₹ 90000 / Piece Get Latest Price
| Module Size | 2x4 ft |
| Cleanroom Class | ISO 5 |
| Installation Type | Hanging |
| Usage/Application | Hospital |
| Filter Type | HEPA H14 |
| Material | 304-SS,JINDAL |
| Airflow Pattern | Unidirectional |
| Brand | SR AIR |
| Surface Finish | Polished |
| Air Flow | VERTICAL |
| Efficiency(%) | 99.99% |
| Model Name/Number | SR-CLAF-24-25 |
| Size | 3X3X2 |
| Height | 2FT |
| Color | SILVER |
Minimum order quantity: 1 Piece
₹ 35000 / Piece Get Latest Price
| Size(ft) | 2 x 2 x 2 |
| Type | Horizontal |
| Usage/Application | Laboratory |
| Surface Finish | GI Coated |
| Efficiency(%) | 99.99% |
| Brand | SR AIR |
| Material | Mild Steel |
| Air Flow | 15+-5M/S |
| Model Name/Number | SR-HLAF-24-25 |
| Size | 2X2X2 |
| Height | 2FT |
| Electrical Socket | 5 Amp |
Minimum order quantity: 1 Piece
Laminar Air Flow refers to a smooth, orderly flow of air in parallel layers or streams, with little to no disruption or turbulence between them. This type of airflow is characterized by a consistent and uniform motion of air molecules along straight or gently curved paths.
Here are the key characteristics of laminar airflow:
Smooth and Steady: Air moves in layers without chaotic fluctuations, meaning that the velocity of the airflow is constant in each layer.
Parallel Layers: The airflow occurs in parallel layers that do not mix or interfere with each other. Each layer flows smoothly over the others, without causing turbulence.
Low Velocity: Laminar flow typically occurs at lower velocities, where air molecules move at a slower pace and in a more uniform direction.
Viscosity Dominance: In laminar flow, the effects of air viscosity are dominant. Higher viscosity results in smoother, laminar flow because it prevents the air from becoming turbulent.
Reynolds Number: The onset of laminar flow is associated with a low Reynolds number (typically less than 2000). This number is a dimensionless quantity that helps predict flow patterns in different fluid dynamics scenarios.
Clean Rooms: Laminar air flow is often used in controlled environments like clean rooms or sterile laboratories where contamination must be minimized. The air is filtered and flows in a smooth, directional pattern to avoid bringing in contaminants.
HVAC Systems: Certain ventilation systems use laminar airflow to maintain air quality and temperature control in sensitive environments.
Aircraft Engineering: In some parts of aircraft, laminar airflow is desirable to reduce drag and improve fuel efficiency.
Unlike turbulent flow, which is chaotic and irregular, laminar flow is highly organized. Turbulent flow, which occurs at higher velocities or with lower viscosity, can lead to swirls, eddies, and vortices in the air, creating much more resistance.
In short, laminar air flow is efficient, stable, and crucial for environments where contamination control or optimal aerodynamic performance is necessary.
₹ 80000 / Piece Get Latest Price
| Size(ft) | 1.5 x 1.5 x 1.5 |
| Type | Vertical |
| Size | 3' X 2' x 2' |
| Surface Finish | Polished |
| Efficiency(%) | 99.99% |
| Material | Stainless Steel |
| Brand | SR AIR |
| Usage/Application | Pharmaceutical Industry |
| Color | Silver |
| Air Flow | 90+-20FPM |
| Electrical Socket | 15 Amp, 5 Amp |
| Country of Origin | Made in India |
Minimum order quantity: 1 Piece
₹ 65500 / Piece Get Latest Price
| Orientation | Horizontal |
| Working Width | 2 ft |
| Size(ft) | 2 x 2 x 2 |
| Cleanroom Class | ISO 5 |
| Type | Horizontal |
| Usage/Application | Laboratory |
| Surface Finish | Matt Finish |
| Material | Stainless Steel |
| Efficiency(%) | 99.99% |
| Brand | SR AIR SYSTEM |
| Air Flow | 15+-5M/S |
Suresh Rajput (Owner)
SR Air System
102/133, Platinum Industrial Park SLM Mill., Gidc, Opp. Jaimin Park, SLM Mill, NR., Narol
Ahmedabad - 382440, Gujarat, India